Product Details:
Plant Application | Industrial RO Plant |
Design | Customized |
Installation/Civil Work | Not Required |
Automatic Grade | Automatic |
Material of Construction | FRP, Stainless Steel |
Max Water Recovery Rate | 50-55 %, 70-75 %, 55-60 %, 65-70 %, >75 %, 60-65 % |
Usage | Water Filter |
Application | Industrial RO plant |
Applications | Pharma,Textile,Power Plant,Chemical Industry and Drinking Water Industry |
Product Details:
Material of Construction | Stainless Steel, FRP |
Operation Mode | Automatic |
Capacity (litres per hour) | 2000-3000 , 200-500, 1000 - 500000 LPH, 1000-2000, 500-1000 |
Types Of Machines | Reverse Osmosis Unit |
Installation/Civil Work | Available |
Max Water Recovery Rate | 60-65 %, 55-60 %, 65-70 %, >75 %, 50-55 %, 70-75 % |
Number of Membranes in RO | 4, 1, 2, 3 |
Application | Industrial RO plant |
Usage | Industry |
Additional Information:
Product Details:
Plant Application | Institutional RO Plant, Industrial RO Plant |
Design | Standard |
Operation Mode | Semi-Automatic, Manual, Automatic |
Automatic Grade | Automatic |
RO Capacity (Liter/hour) | 1000 LTR/Hour |
Types Of Machines | Reverse Osmosis Unit |
Number of Membranes in RO | 4 |
Material of Construction | FRP |
Number of Filtration Passes | 2 |
Brand | waterman |
Raw Water Feeding Pump | Shimage SS 304 1 HP | ||||
Sand filter | FRP 100 LTR pantair | ||||
Activated Carbon filter | FRP 100 LTR pantair | ||||
Antiscalant Dosing Pump | 4 lph | ||||
Bag filter | 4"x20" | ||||
Micron cartridge filter | 5 Microne 20" Long | ||||
High Pressure Pump | 2 Hp Shimage/CRI/LUBY/eq… | ||||
R.O. Element | 4"x40" x 4 element GE/ Torray/ Dow | ||||
Pressure Vessel for Membrane Elements | FRP Pantair 4"x2 element | ||||
Instruments | pressure gauge, rotameter, tds meter | ||||
Electric control panle for RO system | Logic control Auto panel |
Additional Information:
Product Details:
Plant Application | Institutional RO Plant, Industrial RO Plant |
Design | Standard |
Automatic Grade | Automatic, Semi-Automatic |
Operation Mode | Semi-Automatic, Automatic, Manual |
RO Capacity (Liter/hour) | 1500 Ltr/Hour |
Capacity (litres per hour) | 1500 Ltr/Hour |
Automation Grade | Semi-Automatic, Automatic |
Types Of Machines | Reverse Osmosis Unit |
Number of Membranes in RO | 6 |
Material of Construction | FRP |
Number of Filtration Passes | 2 |
Brand | Waterman |
Raw Water Feeding Pump | Shimage SS 304 1 HP | ||||
Sand filter | FRP 150 LTR pantair | ||||
Activated Carbon filter | FRP 150 LTR pantair | ||||
Antiscalant Dosing Pump | 4 lph | ||||
Bag filter | 4"x20" | ||||
Micron cartridge filter | 5 Microne 20" Long | ||||
High Pressure Pump | 2 Hp Shimage/CRI/LUBY/eq… | ||||
R.O. Element | 4"x40" x 6 element GE/ Torray/ Dow | ||||
Pressure Vessel for Membrane Elements | FRP Pantair 4"x 3 element | ||||
Instruments | pressure gauge, rotameter, tds meter | ||||
Electric control panle for RO system | Logic control Auto panel |
Additional Information:
Product Details:
Plant Application | Industrial RO Plant, Institutional RO Plant |
Design | Standard |
Automatic Grade | Automatic, Semi-Automatic |
Operation Mode | Automatic, Semi-Automatic, Manual |
RO Capacity (Liter/hour) | 2000 Ltr/Hour |
Types Of Machines | Reverse Osmosis Unit |
Automation Grade | Semi-Automatic, Automatic |
Material of Construction | FRP |
Number of Filtration Passes | 2 |
Brand | Waterman |
Purification Capacity(in Per Hour) | 2000 Ltr/Hour |
Raw Water Feeding Pump | Shimage SS 304 1.5 HP | ||||
Sand filter | FRP 450 x 1500 mm | ||||
Activated Carbon filter | FRP 450 x 1500 mm | ||||
Antiscalant Dosing Pump | 4 lph | ||||
Bag filter | 4"x20" | ||||
Micron cartridge filter | 5 Microne 20" Long | ||||
High Pressure Pump | 3 Hp Shimage/CRI/LUBY/eq… | ||||
R.O. Element | 8"x40" x 2 element GE/ Torray/ Dow | ||||
Pressure Vessel for Membrane Elements | FRP Pantair 8"x2 element | ||||
Instruments | pressure gauge, rotameter, tds meter | ||||
Electric control panle for RO system | Logic control Auto panel |
Additional Information:
Product Details:
Type Of Purification Plants | Reverse Osmosis |
Plant Application | Institutional RO Plant, Industrial RO Plant |
Material of Construction | FRP |
Design | Standard |
Water Source | Borewell Water |
Water Storage Capacity (litre) | 2500 LPH |
RO Capacity (Liter/hour) | 2500 LPH |
Operation Mode | Manual, Automatic |
Automation Grade | Automatic, Semi-Automatic |
Types Of Machines | Reverse Osmosis Unit |
Number of Membranes in RO | 3 |
Number of Filtration Passes | 2 |
Brand | Waterman |
Raw Water Feeding Pump | Shimage SS 304 1.5 HP | ||||
Sand filter | FRP 450 x 1500 mm | ||||
Activated Carbon filter | FRP 450 x 1500 mm | ||||
Antiscalant Dosing Pump | 4 lph | ||||
Bag filter | 4"x20" | ||||
Micron cartridge filter | 5 Microne 20" Long | ||||
High Pressure Pump | 3 Hp Shimage/CRI/LUBY/eq… | ||||
R.O. Element | 8"x40" x 3 element GE/ Torray/ Dow | ||||
Pressure Vessel for Membrane Elements | FRP Pantair 8"x3 element | ||||
Instruments | pressure gauge, rotameter, tds meter | ||||
Electric control panle for RO system | Logic control Auto panel |
Additional Information:
Product Details:
Type Of Purification Plants | UV, Sand Filtration, Reverse Osmosis |
RO Capacity (Liter/hour) | 3000 LPH |
Design | Standard |
Material of Construction | FRP |
Water Source | Borewell Water |
Automatic Grade | Semi-Automatic, Automatic |
Operation Mode | Manual, Automatic |
Capacity (litres per hour) | 3000 LPH |
Types Of Machines | Reverse Osmosis Unit |
Automation Grade | Semi-Automatic, Automatic |
Number of Filtration Passes | 3 |
Brand/Make | Waterman |
Raw Water Feeding Pump | Shimage SS 304 1.5 HP | ||||
Sand filter | FRP 450 mm x 1500 mm with sand media | ||||
Activated Carbon filter | FRP 450 mm x 1500 mm with Activated carbon media | ||||
Antiscalant Dosing Pump | 4 lph | ||||
Bag filter | 4"x20" | ||||
Micron cartridge filter | 5 Microne 20" Long | ||||
High Pressure Pump | 3 Hp Shimage/CRI/LUBY/eq… | ||||
R.O. Element | 8"x40" x 3 element GE/ Torray/ Dow | ||||
Pressure Vessel for Membrane Elements | FRP Pantair 8"x3 element | ||||
Instruments | pressure gauge, rotameter, tds meter | ||||
Electric control panle for RO system | Logic control Auto panel |
Additional Information:
Product Details:
Type Of Purification Plants | UV, Reverse Osmosis, Sand Filtration |
Material of Construction | FRP |
Design | Standard |
Plant Application | Institutional RO Plant, Industrial RO Plant |
Water Source | Borewell Water |
Automatic Grade | Automatic, Semi-Automatic |
Operation Mode | Semi-Automatic, Automatic, Automatic,Manual,Semi-Automatic, Manual |
Number of Membranes in RO | 4 |
Automation Grade | Automatic, Semi-Automatic |
Types Of Machines | Reverse Osmosis Unit |
Number of Filtration Passes | 2 |
Brand | Waterman |
RO Capacity (LPH) | 4000 LPH |
Raw Water Feeding Pump | Shimage 2 Hp ss304 | ||||
Sand filter | FRP 600 x 1800 mm pantair with sand media | ||||
Activated Carbon filter | FRP 600 x 1800 mm pantair with activated carbon media | ||||
Antiscalant Dosing Pump | 4 lph | ||||
Bag filter | 4"x20" | ||||
Micron cartridge filter | 5 Microne 20" Long | ||||
High Pressure Pump | 5 HP grundfoss / CNP/ Shimage/CRI/LUBY/eq… | ||||
R.O. Element | 8" x 40"x 4 element GE/ Torray/ Dow | ||||
Pressure Vessel for Membrane Elements | FRP paintair make 8"x 2 element | ||||
Instruments | pressure gauge, rotameter, tds meter | ||||
Electric control panle for RO system | Logic control Auto panel |
Additional Information:
Product Details:
Plant Application | Industrial RO Plant, Institutional RO Plant |
Material of Construction | FRP |
Water Source | River Water, Borewell Water |
RO Capacity (Liter/hour) | 5000 LPH |
Automation Grade | Automatic, Semi-Automatic |
Number of Filtration Passes | 2 |
Brand | Waterman |
RO Capacity (LPH) | 5000 LPH |
Raw Water Feeding Pump | Shimage 3 Hp ss304 | 1 No. | ||||
Sand filter | FRP 900 x 1800 mm pantair with sand media | 1 No. | ||||
Activated Carbon filter | FRP 900 x 1800 mm pantair with activated carbon media | 1 No | ||||
Antiscalant Dosing Pump | 4 lph | 1 No. | ||||
Bag filter | 4"x20" | 2 No. | ||||
Micron cartridge filter | 5 Microne 20" Long | 2 No | ||||
High Pressure Pump | 7.5 HP grundfoss / CNP/ Shimage/CRI/LUBY/eq… | 1 No. | ||||
R.O. Element | 8" x 40"x 5 element GE/ Torray/ Dow | 5 No. | ||||
Pressure Vessel for Membrane Elements | FRP paintair make 8"x5 element | 1 No | ||||
Instruments | pressure gauge, rotameter, tds meter | 1 set | ||||
Electric control panle for RO system | Logic control Auto panel | 1 No. |
Additional Information:
Product Details:
Plant Application | Institutional RO Plant, Industrial RO Plant |
Material of Construction | FRP |
Water Source | River Water, Borewell Water |
RO Capacity (Liter/hour) | 6000 LPH |
Operation Mode | Semi-Automatic, Automatic, Manual |
Automation Grade | Automatic, Semi-Automatic |
Brand/Make | Waterman |
Brand | Waterman |
Dimensions (Mtrs) | 6000 LPH |
Raw Water Feeding Pump | Shimage 3 Hp ss304 | 1 No. | ||||
Sand filter | FRP 900 x 1800 mm pantair with sand media | 1 No. | ||||
Activated Carbon filter | FRP 900 x 1800 mm pantair with activated carbon media | 1 No | ||||
Antiscalant Dosing Pump | 4 lph | 1 No. | ||||
Bag filter | 4"x20" | 2 No. | ||||
Micron cartridge filter | 5 Microne 20" Long | 2 No | ||||
High Pressure Pump | 7.5 HP grundfoss / CNP/ Shimage/CRI/LUBY/eq… | 1 No. | ||||
R.O. Element | 8" x 40"x 6 element GE/ Torray/ Dow | 6 No. | ||||
Pressure Vessel for Membrane Elements | FRP paintair make 8"x3 element | 2 No | ||||
Instruments | pressure gauge, rotameter, tds meter | 1 set | ||||
Electric control panle for RO system | Logic control Auto panel | 1 No. |
Additional Information:
Product Details:
Minimum Order Quantity | 851000 Unit |
Plant Application | Industrial RO Plant, Institutional RO Plant |
Type Of Purification Plants | Reverse Osmosis |
Material of Construction | FRP |
Water Source | River Water, Borewell Water |
RO Capacity (Liter/hour) | 8000 LPH |
Operation Mode | Automatic, Semi-Automatic, Manual |
Automation Grade | Semi-Automatic, Automatic |
Brand | Waterman |
EQUIPMENT | SPECIFICATION | QTY | ||||
Raw Water Feeding Pump | Shimage 3 Hp ss304 | 1 No. | ||||
Sand filter | FRP 1050 x 1800 mm pantair with sand media | 1 No. | ||||
Activated Carbon filter | FRP 1050 x 1800 mm pantair with activated carbon media | 1 No | ||||
Antiscalant Dosing Pump | 4 lph | 1 No. | ||||
Bag filter | 4"x20" | 2 No. | ||||
Micron cartridge filter | 5 Microne 20" Long | 2 No | ||||
High Pressure Pump | 10 HP grundfoss / CNP/ Shimage/CRI/LUBY/eq… | 1 No. | ||||
R.O. Element | 8" x 40"x 8 element GE/ Torray/ Dow | 8 No. | ||||
Pressure Vessel for Membrane Elements | FRP paintair make 8"x4 element | 2 No | ||||
Instruments | pressure gauge, rotameter, tds meter | 1 set | ||||
Electric control panle for RO system | Logic control Auto panel | 1 No. |
Additional Information:
Product Details:
Plant Application | Industrial RO Plant, Institutional RO Plant |
Type Of Purification Plants | Reverse Osmosis |
Material of Construction | FRP |
Water Source | Borewell Water, River Water |
RO Capacity (Liter/hour) | 10000 LPH |
Automatic Grade | Automatic, Semi-Automatic |
Brand/Make | Waterman |
Installation Services Required | Yes |
Raw Water Feeding Pump | 5 Hp Grundfos ss 304 | ||||
Sand filter | FRP lined 1050 x 1800 mm with sand media | ||||
Activated Carbon filter | FRP lined 1050 x 1800 mm with Activated carbon media | ||||
Antiscalant Dosing Pump | 6 lph | ||||
Bag filter | 4" X 20"MS FRP lined | ||||
Micron cartridge filter | MS FRP lined 5 Microne 20"x 3 nos | ||||
High Pressure Pump | 10 HP grundfoss / CNP/ Shimage/CRI/LUBY/eq… | ||||
R.O. Element | 8"x40"x12 elements GE/ Torray/ Dow | ||||
Pressure Vessel for Membrane Elements | FRP Paintair make 8"x6 element | ||||
Instruments | pressure gauge, rotameter, tds meter | ||||
Electric control panle for RO system | Logic control Auto panel |
Additional Information:
Product Details:
Plant Application | Institutional RO Plant, Industrial RO Plant |
Material of Construction | FRP |
Water Source | Borewell Water, River Water |
RO Capacity (Liter/hour) | 9000 LPH |
Operation Mode | Semi-Automatic, Manual, Automatic |
Brand | Waterman |
EQUIPMENT | SPECIFICATION | ||||
Raw Water Feeding Pump | Shimage 3 Hp ss304 | ||||
Sand filter | FRP 1050 x 1800 mm pantair with sand media | ||||
Activated Carbon filter | FRP 1050 x 1800 mm pantair with activated carbon media | ||||
Antiscalant Dosing Pump | 4 lph | ||||
Bag filter | 4"x20" | ||||
Micron cartridge filter | 5 Microne 20" Long | ||||
High Pressure Pump | 10 HP grundfoss / CNP/ Shimage/CRI/LUBY/eq… | ||||
R.O. Element | 8"x40"x10 elements GE/ Torray/ Dow | ||||
Pressure Vessel for Membrane Elements | FRP Paintair make 8"x 5 element | ||||
Instruments | pressure gauge, rotameter, tds meter | ||||
Electric control panle for RO system | Logic control Auto panel |
Additional Information: